Miniature Loggers

VLT Vision Series - VLT Loggers

Product Features

  • Temperature Logging & Printing
  • High & low Alarms
  • Alarm delay setting
  • C or F degrees
  • Real time temperature Printing (3 printing modes)
  • Low battery, Chart end and No sensor indicators
  • Data & settings retained after Power failure
  • Normally open contacts for remote alarm

The VLT Vision Logger is designed primarily for transport applications where journey tickets are required. It can also be connected to additional modules which allow, via the Internet, for real time data display and vehicle tracking.

It is also suitable for static installations where print roll is the preferred method of archiving temperature records.

The waterproof sensor supplied is 10 meters long but if required can be extended to 33 meters.

General Technical Specification
Temperature Range-40 to + 130°C
Resolution0.1 °C
Accuracy+ / - 1°C
Sampling Rate1 to 90 minutes
Ambient Operating Temperature Range-18C to +65 °C
Ambient Operating Relative Humidity0 to 95% non-condensing (IP65)
Alarms High & Low, End of paper, No sensor, Low Battery
Alarm delayUser selectable: No Delay, 10 min., 30 mints, 1 hr., 2 hrs.
Output ContactsNormally open volt free contact
Output PCExporting real time data to RS-232 PC port ? No Software needed
3 Printing ModesFull Text report (small font) / Time & temp. (Large font) / Graphics
Stored Data290 Historical Data readings - can be printed on request any time.
Print FormatI.D. number, Date, Time, Temperature, alarm status
Thermal Chart Paper Width2? chart (50.8 cm Width, 40 Meter long) (2 rolled charts supplied)
DisplayNumeric LED Display, 4 characters
Display OptionsOn line temperature display / minimum or maximum on request
Primary power220-240 VAC, 50/60Hz
Alternative power12 Volt dc (vehicle operation with adapter)
Logger Battery backup9 Volt Battery, for logging 50 hours (not supplied)
Clock, setting Battery3.6 Volt Lithium Battery, 2 Years in average use (supplied)
MountingVertical or horizontal - Free standing, wall or panel mount
Case size and Weight208.6 x 135 x 69 mm (8.2? x 5.3? x 2.7?)
Storage Temperature range-40°C to + 65 °C